get:
Show a patch.

patch:
Update a patch.

put:
Update a patch.

GET /api/patches/120066/?format=api
HTTP 200 OK
Allow: GET, PUT, PATCH, HEAD, OPTIONS
Content-Type: application/json
Vary: Accept

{
    "id": 120066,
    "url": "https://patches.dpdk.org/api/patches/120066/?format=api",
    "web_url": "https://patches.dpdk.org/project/dts/patch/20221122082544.2896525-1-weix.ling@intel.com/",
    "project": {
        "id": 3,
        "url": "https://patches.dpdk.org/api/projects/3/?format=api",
        "name": "DTS",
        "link_name": "dts",
        "list_id": "dts.dpdk.org",
        "list_email": "dts@dpdk.org",
        "web_url": "",
        "scm_url": "git://dpdk.org/tools/dts",
        "webscm_url": "http://git.dpdk.org/tools/dts/",
        "list_archive_url": "https://inbox.dpdk.org/dts",
        "list_archive_url_format": "https://inbox.dpdk.org/dts/{}",
        "commit_url_format": ""
    },
    "msgid": "<20221122082544.2896525-1-weix.ling@intel.com>",
    "list_archive_url": "https://inbox.dpdk.org/dts/20221122082544.2896525-1-weix.ling@intel.com",
    "date": "2022-11-22T08:25:44",
    "name": "[V2,1/2] test_plans/vm2vm_virtio_pmd_cbdma_test_plan: modify the dmas parameter by DPDK changed",
    "commit_ref": null,
    "pull_url": null,
    "state": "superseded",
    "archived": false,
    "hash": "2014cda5e00f1456b2be0d5e4ce4aff1f665b0ee",
    "submitter": {
        "id": 1828,
        "url": "https://patches.dpdk.org/api/people/1828/?format=api",
        "name": "Ling, WeiX",
        "email": "weix.ling@intel.com"
    },
    "delegate": null,
    "mbox": "https://patches.dpdk.org/project/dts/patch/20221122082544.2896525-1-weix.ling@intel.com/mbox/",
    "series": [
        {
            "id": 25855,
            "url": "https://patches.dpdk.org/api/series/25855/?format=api",
            "web_url": "https://patches.dpdk.org/project/dts/list/?series=25855",
            "date": "2022-11-22T08:25:35",
            "name": "modify the dmas parameter by DPDK changed",
            "version": 2,
            "mbox": "https://patches.dpdk.org/series/25855/mbox/"
        }
    ],
    "comments": "https://patches.dpdk.org/api/patches/120066/comments/",
    "check": "pending",
    "checks": "https://patches.dpdk.org/api/patches/120066/checks/",
    "tags": {},
    "related": [],
    "headers": {
        "Return-Path": "<dts-bounces@dpdk.org>",
        "X-Original-To": "patchwork@inbox.dpdk.org",
        "Delivered-To": "patchwork@inbox.dpdk.org",
        "Received": [
            "from mails.dpdk.org (mails.dpdk.org [217.70.189.124])\n\tby inbox.dpdk.org (Postfix) with ESMTP id C32F1A057F;\n\tTue, 22 Nov 2022 09:31:37 +0100 (CET)",
            "from mails.dpdk.org (localhost [127.0.0.1])\n\tby mails.dpdk.org (Postfix) with ESMTP id BABAB42D4C;\n\tTue, 22 Nov 2022 09:31:37 +0100 (CET)",
            "from mga06.intel.com (mga06b.intel.com [134.134.136.31])\n by mails.dpdk.org (Postfix) with ESMTP id 345F9427EB\n for <dts@dpdk.org>; Tue, 22 Nov 2022 09:31:36 +0100 (CET)",
            "from fmsmga007.fm.intel.com ([10.253.24.52])\n by orsmga104.jf.intel.com with ESMTP/TLS/ECDHE-RSA-AES256-GCM-SHA384;\n 22 Nov 2022 00:31:35 -0800",
            "from unknown (HELO localhost.localdomain) ([10.239.252.222])\n by fmsmga007-auth.fm.intel.com with ESMTP/TLS/ECDHE-RSA-AES256-GCM-SHA384;\n 22 Nov 2022 00:31:31 -0800"
        ],
        "DKIM-Signature": "v=1; a=rsa-sha256; c=relaxed/simple;\n d=intel.com; i=@intel.com; q=dns/txt; s=Intel;\n t=1669105896; x=1700641896;\n h=from:to:cc:subject:date:message-id:mime-version:\n content-transfer-encoding;\n bh=0cxeP5+GC6cEzZhm1YYiUZarb13wYun7jncCPsG2bVY=;\n b=YxkTQUKFsbw98DPQxeEAtNrLEeOS5PioSeyl5EJR/UIPrfwK5OcaZr0k\n VyE5nMY0HI6wo66PQ+rL9st15Ps/7TXYxwt1ihaijXN2THq8quHsla2yq\n 7NHxo7BaLKvaag0qfxcwEOPikX6KyhepHTBM8Ipq+GskKh3EIT/5/dnvE\n FQ70fryQHpI8oNskD8d2cgpv8V9bXtaT9Zi2wLVMvyNAkKIUOg0rfPKV3\n YcRdyuP0liYat6IeCiM7vxc0DJjvMlAD/YYVG3jigIKRcjUM3OS37FNi7\n fIEWMXciyGDfl90YRl/2ODO1MK942ofmPrvjxOgXaxDva9e6kQPpHidCu Q==;",
        "X-IronPort-AV": [
            "E=McAfee;i=\"6500,9779,10538\"; a=\"375908793\"",
            "E=Sophos;i=\"5.96,183,1665471600\";\n d=\"scan'208,223\";a=\"375908793\"",
            "E=McAfee;i=\"6500,9779,10538\"; a=\"643641672\"",
            "E=Sophos;i=\"5.96,183,1665471600\";\n d=\"scan'208,223\";a=\"643641672\""
        ],
        "From": "Wei Ling <weix.ling@intel.com>",
        "To": "dts@dpdk.org",
        "Cc": "Wei Ling <weix.ling@intel.com>",
        "Subject": "[dts][PATCH V2 1/2] test_plans/vm2vm_virtio_pmd_cbdma_test_plan:\n modify the dmas parameter by DPDK changed",
        "Date": "Tue, 22 Nov 2022 16:25:44 +0800",
        "Message-Id": "<20221122082544.2896525-1-weix.ling@intel.com>",
        "X-Mailer": "git-send-email 2.25.1",
        "MIME-Version": "1.0",
        "Content-Transfer-Encoding": "8bit",
        "X-BeenThere": "dts@dpdk.org",
        "X-Mailman-Version": "2.1.29",
        "Precedence": "list",
        "List-Id": "test suite reviews and discussions <dts.dpdk.org>",
        "List-Unsubscribe": "<https://mails.dpdk.org/options/dts>,\n <mailto:dts-request@dpdk.org?subject=unsubscribe>",
        "List-Archive": "<http://mails.dpdk.org/archives/dts/>",
        "List-Post": "<mailto:dts@dpdk.org>",
        "List-Help": "<mailto:dts-request@dpdk.org?subject=help>",
        "List-Subscribe": "<https://mails.dpdk.org/listinfo/dts>,\n <mailto:dts-request@dpdk.org?subject=subscribe>",
        "Errors-To": "dts-bounces@dpdk.org"
    },
    "content": "From DPDK-22.11, the dmas parameter have been changed by the local patch,\nso modify the dmas parameter in the testplan.\n\nSigned-off-by: Wei Ling <weix.ling@intel.com>\n---\n .../vm2vm_virtio_pmd_cbdma_test_plan.rst      | 574 +++++++++---------\n 1 file changed, 292 insertions(+), 282 deletions(-)",
    "diff": "diff --git a/test_plans/vm2vm_virtio_pmd_cbdma_test_plan.rst b/test_plans/vm2vm_virtio_pmd_cbdma_test_plan.rst\nindex 480f02b9..74dda7bb 100644\n--- a/test_plans/vm2vm_virtio_pmd_cbdma_test_plan.rst\n+++ b/test_plans/vm2vm_virtio_pmd_cbdma_test_plan.rst\n@@ -17,12 +17,23 @@ This document provides the test plan for testing some basic functions with CBDMA\n 1. vm2vm mergeable, non-mergebale path test with virtio 1.0 and virtio1.1 and check virtio-pmd tx chain packets in mergeable path.\n 2. dynamic change queue number.\n \n-..Note:\n-1.For packed virtqueue virtio-net test, need qemu version > 4.2.0 and VM kernel version > 5.1, and packed ring multi-queues not support reconnect in qemu yet.\n-2.For split virtqueue virtio-net with multi-queues server mode test, better to use qemu version >= 5.2.0, dut to qemu(v4.2.0~v5.1.0) exist split ring multi-queues reconnection issue.\n-3.When DMA devices are bound to vfio driver, VA mode is the default and recommended. For PA mode, page by page mapping may\n-exceed IOMMU's max capability, better to use 1G guest hugepage.\n-4.DPDK local patch that about vhost pmd is needed when testing Vhost asynchronous data path with testpmd.\n+.. note::\n+\n+   1.For packed virtqueue virtio-net test, need qemu version > 4.2.0 and VM kernel version > 5.1, and packed ring multi-queues not support reconnect in qemu yet.\n+   2.For split virtqueue virtio-net with multi-queues server mode test, better to use qemu version >= 5.2.0, dut to qemu(v4.2.0~v5.1.0) exist split ring multi-queues reconnection issue.\n+   3.When DMA devices are bound to vfio driver, VA mode is the default and recommended. For PA mode, page by page mapping may\n+   exceed IOMMU's max capability, better to use 1G guest hugepage.\n+   4.DPDK local patch that about vhost pmd is needed when testing Vhost asynchronous data path with testpmd. In this patch,\n+   we enable asynchronous data path for vhostpmd. Asynchronous data path is enabled per tx/rx queue, and users need to specify\n+   the DMA device used by the tx/rx queue. Each tx/rx queue only supports to use one DMA device (This is limited by the\n+   implementation of vhostpmd), but one DMA device can be shared among multiple tx/rx queues of different vhost PMD ports.\n+\n+Two PMD parameters are added:\n+- dmas:\tspecify the used DMA device for a tx/rx queue.(Default: no queues enable asynchronous data path)\n+- dma-ring-size: DMA ring size.(Default: 4096).\n+\n+Here is an example:\n+--vdev 'eth_vhost0,iface=./s0,dmas=[txq0@0000:00.01.0;rxq0@0000:00.01.1],dma-ring-size=2048'\n \n For more about dpdk-testpmd sample, please refer to the DPDK docments:\n https://doc.dpdk.org/guides/testpmd_app_ug/run_app.html\n@@ -37,30 +48,30 @@ Topology\n \n Software\n --------\n-    Trex:http://trex-tgn.cisco.com/trex/release/v2.26.tar.gz\n+    qemu: https://download.qemu.org/qemu-7.1.0.tar.xz\n \n General set up\n --------------\n 1. Compile DPDK::\n \n-    # CC=gcc meson --werror -Denable_kmods=True -Dlibdir=lib -Dexamples=all --default-library=static <dpdk build dir>\n-    # ninja -C <dpdk build dir> -j 110\n-    For example:\n-    CC=gcc meson --werror -Denable_kmods=True -Dlibdir=lib -Dexamples=all --default-library=static x86_64-native-linuxapp-gcc\n-    ninja -C x86_64-native-linuxapp-gcc -j 110\n+       # CC=gcc meson --werror -Denable_kmods=True -Dlibdir=lib -Dexamples=all --default-library=static <dpdk build dir>\n+       # ninja -C <dpdk build dir> -j 110\n+       For example:\n+       CC=gcc meson --werror -Denable_kmods=True -Dlibdir=lib -Dexamples=all --default-library=static x86_64-native-linuxapp-gcc\n+       ninja -C x86_64-native-linuxapp-gcc -j 110\n \n 2. Get the PCI device ID and DMA device ID of DUT, for example, 0000:18:00.0 is PCI device ID, 0000:00:04.0, 0000:00:04.1 is DMA device ID::\n \n-    <dpdk dir># ./usertools/dpdk-devbind.py -s\n+       <dpdk dir># ./usertools/dpdk-devbind.py -s\n \n-    Network devices using kernel driver\n-    ===================================\n-    0000:18:00.0 'Device 159b' if=ens785f0 drv=ice unused=vfio-pci\n+       Network devices using kernel driver\n+       ===================================\n+       0000:18:00.0 'Device 159b' if=ens785f0 drv=ice unused=vfio-pci\n \n-    DMA devices using kernel driver\n-    ===============================\n-    0000:00:04.0 'Sky Lake-E CBDMA Registers 2021' drv=ioatdma unused=vfio-pci\n-    0000:00:04.1 'Sky Lake-E CBDMA Registers 2021' drv=ioatdma unused=vfio-pci\n+       DMA devices using kernel driver\n+       ===============================\n+       0000:00:04.0 'Sky Lake-E CBDMA Registers 2021' drv=ioatdma unused=vfio-pci\n+       0000:00:04.1 'Sky Lake-E CBDMA Registers 2021' drv=ioatdma unused=vfio-pci\n \n Test case\n =========\n@@ -69,205 +80,202 @@ Common steps\n ------------\n 1. Bind 1 NIC port and CBDMA channels to vfio-pci::\n \n-    <dpdk dir># ./usertools/dpdk-devbind.py -b vfio-pci <DUT port pci device id>\n-    <dpdk dir># ./usertools/dpdk-devbind.py -b vfio-pci <DUT port DMA device id>\n+      <dpdk dir># ./usertools/dpdk-devbind.py -b vfio-pci <DUT port pci device id>\n+      <dpdk dir># ./usertools/dpdk-devbind.py -b vfio-pci <DUT port DMA device id>\n \n-    For example, Bind 1 NIC port and 2 CBDMA channels::\n-    <dpdk dir># ./usertools/dpdk-devbind.py -b vfio-pci 0000:00:18.0\n-    <dpdk dir># ./usertools/dpdk-devbind.py -b vfio-pci 0000:00:04.0 0000:00:04.1\n+      For example, Bind 1 NIC port and 2 CBDMA channels::\n+      <dpdk dir># ./usertools/dpdk-devbind.py -b vfio-pci 0000:00:18.0\n+      <dpdk dir># ./usertools/dpdk-devbind.py -b vfio-pci 0000:00:04.0 0000:00:04.1\n \n 2. On VM1 and VM2, bind virtio device(for example,0000:00:05.0) with vfio-pci driver::\n \n-    modprobe vfio\n-    modprobe vfio-pci\n-    echo 1 > /sys/module/vfio/parameters/enable_unsafe_noiommu_mode\n-    <dpdk dir># ./usertools/dpdk-devbind.py --force --bind=vfio-pci 0000:00:05.0\n+      modprobe vfio\n+      modprobe vfio-pci\n+      echo 1 > /sys/module/vfio/parameters/enable_unsafe_noiommu_mode\n+      <dpdk dir># ./usertools/dpdk-devbind.py --force --bind=vfio-pci 0000:00:05.0\n \n Test Case 1: VM2VM virtio-pmd split ring mergeable path dynamic queue size with cbdma enable and server mode\n ------------------------------------------------------------------------------------------------------------\n-This case tests split ring mergeable path in VM2VM vhost-user/virtio-pmd topology when vhost uses the asynchronous operations with CBDMA channels,\n-check that it can work normally after dynamically changing queue number, reconnection has also been tested.\n+This case tests split ring mergeable path in VM2VM vhost-user/virtio-pmd topology when vhost uses the asynchronous\n+operations with CBDMA channels, check that it can work normally after dynamically changing queue number, reconnection has also been tested.\n \n 1. Bind 16 CBDMA channels to vfio-pci, as common step 1.\n \n 2. Launch the testpmd with 2 vhost ports below commands::\n \n-    <dpdk dir># ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -l 1-5 -n 4 --file-prefix=vhost \\\n-    -a 0000:00:04.0 -a 0000:00:04.1 -a 0000:00:04.2 -a 0000:00:04.3 -a 0000:00:04.4 -a 0000:00:04.5 -a 0000:00:04.6 -a 0000:00:04.7 \\\n-    -a 0000:80:04.0 -a 0000:80:04.1 -a 0000:80:04.2 -a 0000:80:04.3 -a 0000:80:04.4 -a 0000:80:04.5 -a 0000:80:04.6 -a 0000:80:04.7 \\\n-    --vdev 'net_vhost0,iface=vhost-net0,client=1,queues=8,dmas=[txq0;txq1;txq2;txq3;rxq0;rxq1;rxq2;rxq3]' \\\n-    --vdev 'net_vhost1,iface=vhost-net1,client=1,queues=8,dmas=[txq0;txq1;txq2;txq3;rxq0;rxq1;rxq2;rxq3]' \\\n-    -- -i --nb-cores=4 --txd=1024 --rxd=1024 --rxq=4 --txq=4 \\\n-    --lcore-dma=[lcore2@0000:00:04.0,lcore2@0000:00:04.1,lcore2@0000:00:04.2,lcore2@0000:00:04.3,lcore3@0000:00:04.4,lcore3@0000:00:04.5,lcore3@0000:00:04.6,lcore3@0000:00:04.7,lcore4@0000:80:04.0,lcore4@0000:80:04.1,lcore4@0000:80:04.2,lcore4@0000:80:04.3,lcore5@0000:80:04.4,lcore5@0000:80:04.5,lcore5@0000:80:04.6,lcore5@0000:80:04.7]\n-    testpmd> start\n+      <dpdk dir># ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -l 1-5 -n 4 --file-prefix=vhost \\\n+      -a 0000:00:04.0 -a 0000:00:04.1 -a 0000:00:04.2 -a 0000:00:04.3 -a 0000:00:04.4 \\\n+      --vdev 'net_vhost0,iface=vhost-net0,client=1,queues=8,dmas=[txq0@0000:00:04.0;txq1@0000:00:04.0;txq2@0000:00:04.1;txq3@0000:00:04.1;rxq0@0000:00:04.0;rxq1@0000:00:04.0;rxq2@0000:00:04.1;rxq3@0000:00:04.1]' \\\n+      --vdev 'net_vhost1,iface=vhost-net1,client=1,queues=8,dmas=[txq0@0000:00:04.2;txq1@0000:00:04.2;txq2@0000:00:04.3;txq3@0000:00:04.3;rxq0@0000:00:04.2;rxq1@0000:00:04.2;rxq2@0000:00:04.3;rxq3@0000:00:04.3]' \\\n+      -- -i --nb-cores=4 --txd=1024 --rxd=1024 --rxq=4 --txq=4\n+      testpmd> start\n \n 3. Launch VM1 and VM2 using qemu::\n \n-    taskset -c 6-16 qemu-system-x86_64 -name vm1 -enable-kvm -cpu host -smp 9 -m 4096 \\\n-    -object memory-backend-file,id=mem,size=4096M,mem-path=/mnt/huge,share=on \\\n-    -numa node,memdev=mem -mem-prealloc -drive file=/home/osimg/ubuntu20-04.img  \\\n-    -chardev socket,path=/tmp/vm1_qga0.sock,server,nowait,id=vm1_qga0 -device virtio-serial \\\n-    -device virtserialport,chardev=vm1_qga0,name=org.qemu.guest_agent.2 -daemonize \\\n-    -monitor unix:/tmp/vm1_monitor.sock,server,nowait -device e1000,netdev=nttsip1 \\\n-    -netdev user,id=nttsip1,hostfwd=tcp:127.0.0.1:6002-:22 \\\n-    -chardev socket,id=char0,path=./vhost-net0,server \\\n-    -netdev type=vhost-user,id=netdev0,chardev=char0,vhostforce,queues=8 \\\n-    -device virtio-net-pci,netdev=netdev0,mac=52:54:00:00:00:01,disable-modern=false,mrg_rxbuf=on,mq=on,vectors=40,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,guest_ufo=on,host_ufo=on -vnc :10\n-\n-    taskset -c 17-27 qemu-system-x86_64 -name vm2 -enable-kvm -cpu host -smp 9 -m 4096 \\\n-    -object memory-backend-file,id=mem,size=4096M,mem-path=/mnt/huge,share=on \\\n-    -numa node,memdev=mem -mem-prealloc -drive file=/home/osimg/ubuntu20-04-2.img  \\\n-    -chardev socket,path=/tmp/vm2_qga0.sock,server,nowait,id=vm2_qga0 -device virtio-serial \\\n-    -device virtserialport,chardev=vm2_qga0,name=org.qemu.guest_agent.2 -daemonize \\\n-    -monitor unix:/tmp/vm2_monitor.sock,server,nowait -device e1000,netdev=nttsip1 \\\n-    -netdev user,id=nttsip1,hostfwd=tcp:127.0.0.1:6003-:22 \\\n-    -chardev socket,id=char0,path=./vhost-net1,server \\\n-    -netdev type=vhost-user,id=netdev0,chardev=char0,vhostforce,queues=8 \\\n-    -device virtio-net-pci,netdev=netdev0,mac=52:54:00:00:00:02,disable-modern=false,mrg_rxbuf=on,mq=on,vectors=40,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,guest_ufo=on,host_ufo=on -vnc :12\n+      taskset -c 6-16 qemu-system-x86_64 -name vm1 -enable-kvm -cpu host -smp 9 -m 4096 \\\n+      -object memory-backend-file,id=mem,size=4096M,mem-path=/mnt/huge,share=on \\\n+      -n uma node,memdev=mem -mem-prealloc -drive file=/home/osimg/ubuntu22-04.img  \\\n+      -chardev socket,path=/tmp/vm1_qga0.sock,server,nowait,id=vm1_qga0 -device virtio-serial \\\n+      -device virtserialport,chardev=vm1_qga0,name=org.qemu.guest_agent.2 -daemonize \\\n+      -monitor unix:/tmp/vm1_monitor.sock,server,nowait -device e1000,netdev=nttsip1 \\\n+      -netdev user,id=nttsip1,hostfwd=tcp:127.0.0.1:6002-:22 \\\n+      -chardev socket,id=char0,path=./vhost-net0,server \\\n+      -netdev type=vhost-user,id=netdev0,chardev=char0,vhostforce,queues=8 \\\n+      -device virtio-net-pci,netdev=netdev0,mac=52:54:00:00:00:01,disable-modern=false,mrg_rxbuf=on,mq=on,vectors=40,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,guest_ufo=on,host_ufo=on -vnc :10\n+\n+      taskset -c 17-27 qemu-system-x86_64 -name vm2 -enable-kvm -cpu host -smp 9 -m 4096 \\\n+      -object memory-backend-file,id=mem,size=4096M,mem-path=/mnt/huge,share=on \\\n+      -numa node,memdev=mem -mem-prealloc -drive file=/home/osimg/ubuntu22-04-2.img  \\\n+      -chardev socket,path=/tmp/vm2_qga0.sock,server,nowait,id=vm2_qga0 -device virtio-serial \\\n+      -device virtserialport,chardev=vm2_qga0,name=org.qemu.guest_agent.2 -daemonize \\\n+      -monitor unix:/tmp/vm2_monitor.sock,server,nowait -device e1000,netdev=nttsip1 \\\n+      -netdev user,id=nttsip1,hostfwd=tcp:127.0.0.1:6003-:22 \\\n+      -chardev socket,id=char0,path=./vhost-net1,server \\\n+      -netdev type=vhost-user,id=netdev0,chardev=char0,vhostforce,queues=8 \\\n+      -device virtio-net-pci,netdev=netdev0,mac=52:54:00:00:00:02,disable-modern=false,mrg_rxbuf=on,mq=on,vectors=40,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,guest_ufo=on,host_ufo=on -vnc :12\n \n 4. On VM1 and VM2, bind virtio device with vfio-pci driver::\n \n-    modprobe vfio\n-    modprobe vfio-pci\n-    echo 1 > /sys/module/vfio/parameters/enable_unsafe_noiommu_mode\n-    ./usertools/dpdk-devbind.py --force --bind=vfio-pci 0000:00:05.0\n+      modprobe vfio\n+      modprobe vfio-pci\n+      echo 1 > /sys/module/vfio/parameters/enable_unsafe_noiommu_mode\n+      ./usertools/dpdk-devbind.py --force --bind=vfio-pci 0000:00:05.0\n \n 5. Launch testpmd in VM1::\n \n-    ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -c 0x3 -n 4 -- -i --tx-offloads=0x00 --enable-hw-vlan-strip --txq=8 --rxq=8 --txd=1024 --rxd=1024 --max-pkt-len=9600 --rx-offloads=0x00002000\n-    testpmd> set fwd mac\n-    testpmd> start\n+      ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -c 0x3 -n 4 -- -i --tx-offloads=0x00 --enable-hw-vlan-strip --txq=8 --rxq=8 --txd=1024 --rxd=1024 --max-pkt-len=9600 --rx-offloads=0x00002000\n+      testpmd> set fwd mac\n+      testpmd> start\n \n-6. Launch testpmd in VM2 and send imix pkts, check imix packets can looped between two VMs for 1 mins and 4 queues (queue0 to queue3) have packets rx/tx::\n+6. Launch testpmd in VM2 and send imix packets, check imix packets can loop between two VMs for 1 mins and 4 queues (queue0 to queue3) have packets rx/tx::\n \n-    ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -c 0x3 -n 4 -- -i --tx-offloads=0x00 --enable-hw-vlan-strip --txq=8 --rxq=8 --txd=1024 --rxd=1024 --max-pkt-len=9600 --rx-offloads=0x00002000\n-    testpmd> set fwd mac\n-    testpmd> set txpkts 64,256,512,1024,2000,64,256,512,1024,2000\n-    testpmd> start tx_first 32\n-    testpmd> show port stats all\n+      ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -c 0x3 -n 4 -- -i --tx-offloads=0x00 --enable-hw-vlan-strip --txq=8 --rxq=8 --txd=1024 --rxd=1024 --max-pkt-len=9600 --rx-offloads=0x00002000\n+      testpmd> set fwd mac\n+      testpmd> set txpkts 64,256,512,1024,2000,64,256,512,1024,2000\n+      testpmd> start tx_first 32\n+      testpmd> show port stats all\n \n 7. Check vhost use the asynchronous data path(funtion like virtio_dev_rx_async_xxx/virtio_dev_tx_async_xxx)::\n \n-    perf top\n+      perf top\n \n 8. On host, dynamic change queue numbers::\n \n-    testpmd> stop\n-    testpmd> port stop all\n-    testpmd> port config all rxq 8\n-    testpmd> port config all txq 8\n-    testpmd> port start all\n-    testpmd> start\n+      testpmd> stop\n+      testpmd> port stop all\n+      testpmd> port config all rxq 8\n+      testpmd> port config all txq 8\n+      testpmd> port start all\n+      testpmd> start\n \n 9. Send packets by testpmd in VM2::\n \n-    testpmd> stop\n-    testpmd> start tx_first 32\n-    testpmd> show port stats all\n+      testpmd> stop\n+      testpmd> start tx_first 32\n+      testpmd> show port stats all\n \n-10. Check vhost testpmd RX/TX can work normally, packets can looped between two VMs and both 8 queues can RX/TX traffic.\n+10. Check vhost testpmd RX/TX can work normally, packets can loop between two VMs and both 8 queues can RX/TX traffic.\n \n 11. Rerun step 7.\n \n 12. Relaunch and start vhost side testpmd with 8 queues::\n \n-\t./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -l 1-5 -n 4 --file-prefix=vhost \\\n-\t-a 0000:00:04.0 -a 0000:00:04.1 -a 0000:00:04.2 -a 0000:00:04.3 -a 0000:00:04.4 -a 0000:00:04.5 -a 0000:00:04.6 -a 0000:00:04.7 \\\n-\t-a 0000:80:04.0 -a 0000:80:04.1 -a 0000:80:04.2 -a 0000:80:04.3 -a 0000:80:04.4 -a 0000:80:04.5 -a 0000:80:04.6 -a 0000:80:04.7 \\\n-\t--vdev 'net_vhost0,iface=vhost-net0,client=1,queues=8,dmas=[txq0;txq1;txq2;txq3;txq4;txq5;rxq2;rxq3;rxq4;rxq5;rxq6;rxq7]' \\\n-\t--vdev 'net_vhost1,iface=vhost-net1,client=1,queues=8,dmas=[txq0;txq1;txq2;txq3;txq4;txq5;rxq2;rxq3;rxq4;rxq5;rxq6;rxq7]' \\\n-\t-- -i --nb-cores=4 --txd=1024 --rxd=1024 --rxq=8 --txq=8 \\\n-\t--lcore-dma=[lcore2@0000:00:04.0,lcore2@0000:00:04.1,lcore2@0000:00:04.2,lcore2@0000:00:04.3,lcore3@0000:00:04.4,lcore3@0000:00:04.5,lcore3@0000:00:04.6,lcore3@0000:00:04.7,lcore4@0000:80:04.0,lcore4@0000:80:04.1,lcore4@0000:80:04.2,lcore4@0000:80:04.3,lcore5@0000:80:04.4,lcore5@0000:80:04.5,lcore5@0000:80:04.6,lcore5@0000:80:04.7]\n-\ttestpmd> start\n+      ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -l 1-5 -n 4 --file-prefix=vhost \\\n+      -a 0000:00:04.0 -a 0000:00:04.1 -a 0000:00:04.2 -a 0000:00:04.3 -a 0000:00:04.4 -a 0000:00:04.5 -a 0000:00:04.6 -a 0000:00:04.7 \\\n+      -a 0000:80:04.0 -a 0000:80:04.1 -a 0000:80:04.2 -a 0000:80:04.3 -a 0000:80:04.4 -a 0000:80:04.5 -a 0000:80:04.6 -a 0000:80:04.7 \\\n+      --vdev 'net_vhost0,iface=vhost-net0,client=1,queues=8,dmas=[txq0@0000:00:04.0;txq1@0000:00:04.1;txq2@0000:00:04.2;txq3@0000:00:04.3;txq4@0000:00:04.4;txq5@0000:00:04.1;rxq2@0000:00:04.2;rxq3@0000:00:04.3;rxq4@0000:00:04.4;rxq5@0000:00:04.5;rxq6@0000:00:04.6;rxq7@0000:00:04.7]' \\\n+      --vdev 'net_vhost1,iface=vhost-net1,client=1,queues=8,dmas=[txq0@0000:80:04.0;txq1@0000:80:04.1;txq2@0000:80:04.2;txq3@0000:80:04.3;txq4@0000:80:04.4;txq5@0000:80:04.1;rxq2@0000:80:04.2;rxq3@0000:80:04.3;rxq4@0000:80:04.4;rxq5@0000:80:04.5;rxq6@0000:80:04.6;rxq7@0000:80:04.7]' \\\n+      -- -i --nb-cores=4 --txd=1024 --rxd=1024 --rxq=8 --txq=8\n+      testpmd> set fwd mac\n+      testpmd> start\n \n-13. Send packets by testpmd in VM2, check imix packets can looped between two VMs for 1 mins and 8 queues all have packets rx/tx::\n+13. Send packets by testpmd in VM2, check imix packets can loop between two VMs for 1 mins and 8 queues all have packets rx/tx::\n \n-\ttestpmd> stop\n-\ttestpmd> start tx_first 32\n-\ttestpmd> show port stats all\n+      testpmd> stop\n+      testpmd> start tx_first 32\n+      testpmd> show port stats all\n \n-14. Rerun step 12-13 for 5 times.\n+14. Rerun step 12-13 for 3 times.\n \n Test Case 2: VM2VM virtio-pmd split ring non-mergeable path dynamic queue size with cbdma enable and server mode\n ----------------------------------------------------------------------------------------------------------------\n-This case tests split ring non-mergeable path in VM2VM vhost-user/virtio-pmd topology when vhost uses the asynchronous operations with CBDMA channels,\n-check that it can work normally after dynamically changing queue number, reconnection has also been tested.\n+This case tests split ring non-mergeable path in VM2VM vhost-user/virtio-pmd topology when vhost uses the asynchronous\n+operations with CBDMA channels, check that it can work normally after dynamically changing queue number, reconnection has also been tested.\n \n 1. Bind 16 CBDMA channels to vfio-pci, as common step 1.\n \n 2. Launch the testpmd with 2 vhost ports below commands::\n \n-    ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -l 1-5 -n 4 --file-prefix=vhost -a 0000:00:04.0 -a 0000:00:04.1 -a 0000:00:04.2 -a 0000:00:04.3 -a 0000:00:04.4 -a 0000:00:04.5 -a 0000:00:04.6 -a 0000:00:04.7 \\\n-    -a 0000:80:04.0 -a 0000:80:04.1 -a 0000:80:04.2 -a 0000:80:04.3 -a 0000:80:04.4 -a 0000:80:04.5 -a 0000:80:04.6 -a 0000:80:04.7 \\\n-    --vdev 'net_vhost0,iface=vhost-net0,client=1,queues=8,dmas=[txq0;txq1;txq2;txq3;rxq0;rxq1;rxq2;rxq3]' \\\n-    --vdev 'net_vhost1,iface=vhost-net1,client=1,queues=8,dmas=[txq0;txq1;txq2;txq3;rxq0;rxq1;rxq2;rxq3]' \\\n-    -- -i --nb-cores=4 --txd=1024 --rxd=1024 --rxq=4 --txq=4 \\\n-    --lcore-dma=[lcore2@0000:00:04.0,lcore2@0000:00:04.1,lcore2@0000:00:04.2,lcore2@0000:00:04.3,lcore3@0000:00:04.4,lcore3@0000:00:04.5,lcore3@0000:00:04.6,lcore3@0000:00:04.7,lcore4@0000:80:04.0,lcore4@0000:80:04.1,lcore4@0000:80:04.2,lcore4@0000:80:04.3,lcore5@0000:80:04.4,lcore5@0000:80:04.5,lcore5@0000:80:04.6,lcore5@0000:80:04.7]\n-    testpmd> start\n+      ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -l 1-5 -n 4 --file-prefix=vhost \\\n+      -a 0000:00:04.0 -a 0000:00:04.1 -a 0000:00:04.2 -a 0000:00:04.3 -a 0000:00:04.4 \\\n+      --vdev 'net_vhost0,iface=vhost-net0,client=1,queues=8,dmas=[txq0@0000:00:04.0;txq1@0000:00:04.0;txq2@0000:00:04.1;txq3@0000:00:04.1;rxq0@0000:00:04.0;rxq1@0000:00:04.0;rxq2@0000:00:04.1;rxq3@0000:00:04.1]' \\\n+      --vdev 'net_vhost1,iface=vhost-net1,client=1,queues=8,dmas=[txq0@0000:00:04.0;txq1@0000:00:04.0;txq2@0000:00:04.1;txq3@0000:00:04.1;rxq0@0000:00:04.0;rxq1@0000:00:04.0;rxq2@0000:00:04.1;rxq3@0000:00:04.1]' \\\n+      -- -i --nb-cores=4 --txd=1024 --rxd=1024 --rxq=4 --txq=4\n+      testpmd> start\n \n 3. Launch VM1 and VM2 using qemu::\n \n-    taskset -c 6-16 qemu-system-x86_64 -name vm1 -enable-kvm -cpu host -smp 9 -m 4096 \\\n-    -object memory-backend-file,id=mem,size=4096M,mem-path=/mnt/huge,share=on \\\n-    -numa node,memdev=mem -mem-prealloc -drive file=/home/osimg/ubuntu20-04.img  \\\n-    -chardev socket,path=/tmp/vm1_qga0.sock,server,nowait,id=vm1_qga0 -device virtio-serial \\\n-    -device virtserialport,chardev=vm1_qga0,name=org.qemu.guest_agent.2 -daemonize \\\n-    -monitor unix:/tmp/vm1_monitor.sock,server,nowait -device e1000,netdev=nttsip1 \\\n-    -netdev user,id=nttsip1,hostfwd=tcp:127.0.0.1:6002-:22 \\\n-    -chardev socket,id=char0,path=./vhost-net0,server \\\n-    -netdev type=vhost-user,id=netdev0,chardev=char0,vhostforce,queues=8 \\\n-    -device virtio-net-pci,netdev=netdev0,mac=52:54:00:00:00:01,disable-modern=false,mrg_rxbuf=off,mq=on,vectors=40,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,guest_ufo=on,host_ufo=on -vnc :10\n-\n-    taskset -c 17-27 qemu-system-x86_64 -name vm2 -enable-kvm -cpu host -smp 9 -m 4096 \\\n-    -object memory-backend-file,id=mem,size=4096M,mem-path=/mnt/huge,share=on \\\n-    -numa node,memdev=mem -mem-prealloc -drive file=/home/osimg/ubuntu20-04-2.img  \\\n-    -chardev socket,path=/tmp/vm2_qga0.sock,server,nowait,id=vm2_qga0 -device virtio-serial \\\n-    -device virtserialport,chardev=vm2_qga0,name=org.qemu.guest_agent.2 -daemonize \\\n-    -monitor unix:/tmp/vm2_monitor.sock,server,nowait -device e1000,netdev=nttsip1 \\\n-    -netdev user,id=nttsip1,hostfwd=tcp:127.0.0.1:6003-:22 \\\n-    -chardev socket,id=char0,path=./vhost-net1,server \\\n-    -netdev type=vhost-user,id=netdev0,chardev=char0,vhostforce,queues=8 \\\n-    -device virtio-net-pci,netdev=netdev0,mac=52:54:00:00:00:02,disable-modern=false,mrg_rxbuf=off,mq=on,vectors=40,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,guest_ufo=on,host_ufo=on -vnc :12\n+      taskset -c 6-16 qemu-system-x86_64 -name vm1 -enable-kvm -cpu host -smp 9 -m 4096 \\\n+      -object memory-backend-file,id=mem,size=4096M,mem-path=/mnt/huge,share=on \\\n+      -numa node,memdev=mem -mem-prealloc -drive file=/home/osimg/ubuntu22-04.img  \\\n+      -chardev socket,path=/tmp/vm1_qga0.sock,server,nowait,id=vm1_qga0 -device virtio-serial \\\n+      -device virtserialport,chardev=vm1_qga0,name=org.qemu.guest_agent.2 -daemonize \\\n+      -monitor unix:/tmp/vm1_monitor.sock,server,nowait -device e1000,netdev=nttsip1 \\\n+      -netdev user,id=nttsip1,hostfwd=tcp:127.0.0.1:6002-:22 \\\n+      -chardev socket,id=char0,path=./vhost-net0,server \\\n+      -netdev type=vhost-user,id=netdev0,chardev=char0,vhostforce,queues=8 \\\n+      -device virtio-net-pci,netdev=netdev0,mac=52:54:00:00:00:01,disable-modern=false,mrg_rxbuf=off,mq=on,vectors=40,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,guest_ufo=on,host_ufo=on -vnc :10\n+\n+      taskset -c 17-27 qemu-system-x86_64 -name vm2 -enable-kvm -cpu host -smp 9 -m 4096 \\\n+      -object memory-backend-file,id=mem,size=4096M,mem-path=/mnt/huge,share=on \\\n+      -numa node,memdev=mem -mem-prealloc -drive file=/home/osimg/ubuntu22-04-2.img  \\\n+      -chardev socket,path=/tmp/vm2_qga0.sock,server,nowait,id=vm2_qga0 -device virtio-serial \\\n+      -device virtserialport,chardev=vm2_qga0,name=org.qemu.guest_agent.2 -daemonize \\\n+      -monitor unix:/tmp/vm2_monitor.sock,server,nowait -device e1000,netdev=nttsip1 \\\n+      -netdev user,id=nttsip1,hostfwd=tcp:127.0.0.1:6003-:22 \\\n+      -chardev socket,id=char0,path=./vhost-net1,server \\\n+      -netdev type=vhost-user,id=netdev0,chardev=char0,vhostforce,queues=8 \\\n+      -device virtio-net-pci,netdev=netdev0,mac=52:54:00:00:00:02,disable-modern=false,mrg_rxbuf=off,mq=on,vectors=40,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,guest_ufo=on,host_ufo=on -vnc :12\n \n 4. On VM1 and VM2, bind virtio device with vfio-pci driver::\n \n-    modprobe vfio\n-    modprobe vfio-pci\n-    echo 1 > /sys/module/vfio/parameters/enable_unsafe_noiommu_mode\n-    ./usertools/dpdk-devbind.py --force --bind=vfio-pci 0000:00:05.0\n+      modprobe vfio\n+      modprobe vfio-pci\n+      echo 1 > /sys/module/vfio/parameters/enable_unsafe_noiommu_mode\n+      ./usertools/dpdk-devbind.py --force --bind=vfio-pci 0000:00:05.0\n \n 5. Launch testpmd in VM1::\n \n-    ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -c 0x3 -n 4 -- -i --tx-offloads=0x00 --enable-hw-vlan-strip --txq=8 --rxq=8 --txd=1024 --rxd=1024\n-    testpmd> set fwd mac\n-    testpmd> start\n+      ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -c 0x3 -n 4 -- -i --tx-offloads=0x00 --enable-hw-vlan-strip --txq=8 --rxq=8 --txd=1024 --rxd=1024\n+      testpmd> set fwd mac\n+      testpmd> start\n \n-6. Launch testpmd in VM2 and send imix pkts, check imix packets can looped between two VMs for 1 mins and 4 queues (queue0 to queue3) have packets rx/tx::\n+6. Launch testpmd in VM2 and send imix pkts, check imix packets can loop between two VMs for 1 mins and 4 queues (queue0 to queue3) have packets rx/tx::\n \n-    ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -c 0x3 -n 4 -- -i --tx-offloads=0x00 --enable-hw-vlan-strip --txq=8 --rxq=8 --txd=1024 --rxd=1024\n-    testpmd> set fwd mac\n-    testpmd> set txpkts 64,256,512\n-    testpmd> start tx_first 32\n-    testpmd> show port stats all\n+      ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -c 0x3 -n 4 -- -i --tx-offloads=0x00 --enable-hw-vlan-strip --txq=8 --rxq=8 --txd=1024 --rxd=1024\n+      testpmd> set fwd mac\n+      testpmd> set txpkts 64,256,512\n+      testpmd> start tx_first 32\n+      testpmd> show port stats all\n \n 7. Check vhost use the asynchronous data path(funtion like virtio_dev_rx_async_xxx/virtio_dev_tx_async_xxx)::\n \n-    perf top\n+      perf top\n \n 8. On VM1 and VM2, dynamic change queue numbers at virtio-pmd side from 8 queues to 4 queues::\n \n-    testpmd> stop\n-    testpmd> port stop all\n-    testpmd> port config all rxq 4\n-    testpmd> port config all txq 4\n-    testpmd> port start all\n-    testpmd> start\n+      testpmd> stop\n+      testpmd> port stop all\n+      testpmd> port config all rxq 4\n+      testpmd> port config all txq 4\n+      testpmd> port start all\n+      testpmd> start\n \n-9. Send packets by testpmd in VM2, check Check virtio-pmd RX/TX can work normally and imix packets can looped between two VMs for 1 mins::\n+9. Send packets by testpmd in VM2, check Check virtio-pmd RX/TX can work normally and imix packets can loop between two VMs for 1 mins::\n \n-    testpmd> stop\n-    testpmd> start tx_first 32\n-    testpmd> show port stats all\n+      testpmd> stop\n+      testpmd> start tx_first 32\n+      testpmd> show port stats all\n \n 10. Rerun step 7.\n \n@@ -275,205 +283,207 @@ check that it can work normally after dynamically changing queue number, reconne\n \n Test Case 3: VM2VM virtio-pmd packed ring mergeable path dynamic queue size with cbdma enable and server mode\n -------------------------------------------------------------------------------------------------------------\n-This case tests packed ring mergeable path with virtio1.1 and server mode in VM2VM vhost-user/virtio-pmd topology when vhost uses the asynchronous operations with CBDMA channels,check that it can work normally after dynamically changing queue number.\n+This case tests packed ring mergeable path with virtio1.1 and server mode in VM2VM vhost-user/virtio-pmd topology\n+when vhost uses the asynchronous operations with CBDMA channels, check that it can work normally after dynamically changing queue number.\n \n 1. Bind 16 CBDMA channels to vfio-pci, as common step 1.\n \n 2. Launch the testpmd with 2 vhost ports below commands::\n \n-    ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -l 1-5 -n 4 --file-prefix=vhost -a 0000:00:04.0 -a 0000:00:04.1 -a 0000:00:04.2 -a 0000:00:04.3 -a 0000:00:04.4 -a 0000:00:04.5 -a 0000:00:04.6 -a 0000:00:04.7 \\\n-    -a 0000:80:04.0 -a 0000:80:04.1 -a 0000:80:04.2 -a 0000:80:04.3 -a 0000:80:04.4 -a 0000:80:04.5 -a 0000:80:04.6 -a 0000:80:04.7 \\\n-    --vdev 'net_vhost0,iface=vhost-net0,client=1,queues=8,dmas=[txq0;txq1;txq2;txq3;rxq0;rxq1;rxq2;rxq3]' \\\n-    --vdev 'net_vhost1,iface=vhost-net1,client=1,queues=8,dmas=[txq0;txq1;txq2;txq3;rxq0;rxq1;rxq2;rxq3]' \\\n-    -- -i --nb-cores=4 --txd=1024 --rxd=1024 --rxq=4 --txq=4 \\\n-    --lcore-dma=[lcore2@0000:00:04.0,lcore2@0000:00:04.1,lcore2@0000:00:04.2,lcore2@0000:00:04.3,lcore3@0000:00:04.4,lcore3@0000:00:04.5,lcore3@0000:00:04.6,lcore3@0000:00:04.7,lcore4@0000:80:04.0,lcore4@0000:80:04.1,lcore4@0000:80:04.2,lcore4@0000:80:04.3,lcore5@0000:80:04.4,lcore5@0000:80:04.5,lcore5@0000:80:04.6,lcore5@0000:80:04.7]\n-    testpmd> start\n+      ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -l 1-5 -n 4 --file-prefix=vhost \\\n+      -a 0000:00:04.0 -a 0000:00:04.1 -a 0000:00:04.2 -a 0000:00:04.3 -a 0000:00:04.4 \\\n+      --vdev 'net_vhost0,iface=vhost-net0,client=1,queues=8,dmas=[txq0@0000:00:04.0;txq1@0000:00:04.0;txq2@0000:00:04.1;txq3@0000:00:04.1;rxq0@0000:00:04.0;rxq1@0000:00:04.0;rxq2@0000:00:04.1;rxq3@0000:00:04.1]' \\\n+      --vdev 'net_vhost1,iface=vhost-net1,client=1,queues=8,dmas=[txq0@0000:00:04.0;txq1@0000:00:04.0;txq2@0000:00:04.1;txq3@0000:00:04.1;rxq0@0000:00:04.0;rxq1@0000:00:04.0;rxq2@0000:00:04.1;rxq3@0000:00:04.1]' \\\n+      -- -i --nb-cores=4 --txd=1024 --rxd=1024 --rxq=4 --txq=4\n+      testpmd> set fwd mac\n+      testpmd> start\n \n 3. Launch VM1 and VM2 using qemu::\n \n-    taskset -c 6-16 qemu-system-x86_64 -name vm1 -enable-kvm -cpu host -smp 9 -m 4096 \\\n-    -object memory-backend-file,id=mem,size=4096M,mem-path=/mnt/huge,share=on \\\n-    -numa node,memdev=mem -mem-prealloc -drive file=/home/osimg/ubuntu20-04.img  \\\n-    -chardev socket,path=/tmp/vm1_qga0.sock,server,nowait,id=vm1_qga0 -device virtio-serial \\\n-    -device virtserialport,chardev=vm1_qga0,name=org.qemu.guest_agent.2 -daemonize \\\n-    -monitor unix:/tmp/vm1_monitor.sock,server,nowait -device e1000,netdev=nttsip1 \\\n-    -netdev user,id=nttsip1,hostfwd=tcp:127.0.0.1:6002-:22 \\\n-    -chardev socket,id=char0,path=./vhost-net0,server \\\n-    -netdev type=vhost-user,id=netdev0,chardev=char0,vhostforce,queues=8 \\\n-    -device virtio-net-pci,netdev=netdev0,mac=52:54:00:00:00:01,disable-modern=false,mrg_rxbuf=on,mq=on,vectors=40,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,guest_ufo=on,host_ufo=on,packed=on -vnc :10\n-\n-    taskset -c 17-27 qemu-system-x86_64 -name vm2 -enable-kvm -cpu host -smp 9 -m 4096 \\\n-    -object memory-backend-file,id=mem,size=4096M,mem-path=/mnt/huge,share=on \\\n-    -numa node,memdev=mem -mem-prealloc -drive file=/home/osimg/ubuntu20-04-2.img  \\\n-    -chardev socket,path=/tmp/vm2_qga0.sock,server,nowait,id=vm2_qga0 -device virtio-serial \\\n-    -device virtserialport,chardev=vm2_qga0,name=org.qemu.guest_agent.2 -daemonize \\\n-    -monitor unix:/tmp/vm2_monitor.sock,server,nowait -device e1000,netdev=nttsip1 \\\n-    -netdev user,id=nttsip1,hostfwd=tcp:127.0.0.1:6003-:22 \\\n-    -chardev socket,id=char0,path=./vhost-net1,server \\\n-    -netdev type=vhost-user,id=netdev0,chardev=char0,vhostforce,queues=8 \\\n-    -device virtio-net-pci,netdev=netdev0,mac=52:54:00:00:00:02,disable-modern=false,mrg_rxbuf=on,mq=on,vectors=40,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,guest_ufo=on,host_ufo=on,packed=on -vnc :12\n+      taskset -c 6-16 qemu-system-x86_64 -name vm1 -enable-kvm -cpu host -smp 9 -m 4096 \\\n+      -object memory-backend-file,id=mem,size=4096M,mem-path=/mnt/huge,share=on \\\n+      -numa node,memdev=mem -mem-prealloc -drive file=/home/osimg/ubuntu22-04.img  \\\n+      -chardev socket,path=/tmp/vm1_qga0.sock,server,nowait,id=vm1_qga0 -device virtio-serial \\\n+      -device virtserialport,chardev=vm1_qga0,name=org.qemu.guest_agent.2 -daemonize \\\n+      -monitor unix:/tmp/vm1_monitor.sock,server,nowait -device e1000,netdev=nttsip1 \\\n+      -netdev user,id=nttsip1,hostfwd=tcp:127.0.0.1:6002-:22 \\\n+      -chardev socket,id=char0,path=./vhost-net0,server \\\n+      -netdev type=vhost-user,id=netdev0,chardev=char0,vhostforce,queues=8 \\\n+      -device virtio-net-pci,netdev=netdev0,mac=52:54:00:00:00:01,disable-modern=false,mrg_rxbuf=on,mq=on,vectors=40,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,guest_ufo=on,host_ufo=on,packed=on -vnc :10\n+\n+      taskset -c 17-27 qemu-system-x86_64 -name vm2 -enable-kvm -cpu host -smp 9 -m 4096 \\\n+      -object memory-backend-file,id=mem,size=4096M,mem-path=/mnt/huge,share=on \\\n+      -numa node,memdev=mem -mem-prealloc -drive file=/home/osimg/ubuntu22-04-2.img  \\\n+      -chardev socket,path=/tmp/vm2_qga0.sock,server,nowait,id=vm2_qga0 -device virtio-serial \\\n+      -device virtserialport,chardev=vm2_qga0,name=org.qemu.guest_agent.2 -daemonize \\\n+      -monitor unix:/tmp/vm2_monitor.sock,server,nowait -device e1000,netdev=nttsip1 \\\n+      -netdev user,id=nttsip1,hostfwd=tcp:127.0.0.1:6003-:22 \\\n+      -chardev socket,id=char0,path=./vhost-net1,server \\\n+      -netdev type=vhost-user,id=netdev0,chardev=char0,vhostforce,queues=8 \\\n+      -device virtio-net-pci,netdev=netdev0,mac=52:54:00:00:00:02,disable-modern=false,mrg_rxbuf=on,mq=on,vectors=40,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,guest_ufo=on,host_ufo=on,packed=on -vnc :12\n \n 4. On VM1 and VM2, bind virtio device with vfio-pci driver::\n \n-    modprobe vfio\n-    modprobe vfio-pci\n-    echo 1 > /sys/module/vfio/parameters/enable_unsafe_noiommu_mode\n-    ./usertools/dpdk-devbind.py --force --bind=vfio-pci 0000:00:05.0\n+      modprobe vfio\n+      modprobe vfio-pci\n+      echo 1 > /sys/module/vfio/parameters/enable_unsafe_noiommu_mode\n+      ./usertools/dpdk-devbind.py --force --bind=vfio-pci 0000:00:05.0\n \n 5. Launch testpmd in VM1::\n \n-    ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -c 0x3 -n 4 -- -i --tx-offloads=0x00 --enable-hw-vlan-strip --txq=8 --rxq=8 --txd=1024 --rxd=1024 --max-pkt-len=9600 --rx-offloads=0x00002000\n-    testpmd> set mac fwd\n-    testpmd> start\n+      ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -c 0x3 -n 4 -- -i --tx-offloads=0x00 --enable-hw-vlan-strip --txq=8 --rxq=8 --txd=1024 --rxd=1024 --max-pkt-len=9600 --rx-offloads=0x00002000\n+      testpmd> set mac fwd\n+      testpmd> start\n \n-6. Launch testpmd in VM2 and send imix pkts, check imix packets can looped between two VMs for 1 mins and 4 queues (queue0 to queue3) have packets rx/tx::\n+6. Launch testpmd in VM2 and send imix pkts, check imix packets can loop between two VMs for 1 mins and 4 queues (queue0 to queue3) have packets rx/tx::\n \n-    ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -c 0x3 -n 4 -- -i --tx-offloads=0x00 --enable-hw-vlan-strip --txq=8 --rxq=8 --txd=1024 --rxd=1024 --max-pkt-len=9600 --rx-offloads=0x00002000\n-    testpmd> set mac fwd\n-    testpmd> set txpkts 64,256,512,1024,2000,64,256,512,1024,2000\n-    testpmd> start tx_first 32\n-    testpmd> show port stats all\n-    testpmd> stop\n+      ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -c 0x3 -n 4 -- -i --tx-offloads=0x00 --enable-hw-vlan-strip --txq=8 --rxq=8 --txd=1024 --rxd=1024 --max-pkt-len=9600 --rx-offloads=0x00002000\n+      testpmd> set mac fwd\n+      testpmd> set txpkts 64,256,512,1024,2000,64,256,512,1024,2000\n+      testpmd> start tx_first 32\n+      testpmd> show port stats all\n+      testpmd> stop\n \n 7. Quit VM2 and relaunch VM2 with split ring::\n \n-    taskset -c 17-27 qemu-system-x86_64 -name vm2 -enable-kvm -cpu host -smp 9 -m 4096 \\\n-    -object memory-backend-file,id=mem,size=4096M,mem-path=/mnt/huge,share=on \\\n-    -numa node,memdev=mem -mem-prealloc -drive file=/home/osimg/ubuntu20-04-2.img  \\\n-    -chardev socket,path=/tmp/vm2_qga0.sock,server,nowait,id=vm2_qga0 -device virtio-serial \\\n-    -device virtserialport,chardev=vm2_qga0,name=org.qemu.guest_agent.2 -daemonize \\\n-    -monitor unix:/tmp/vm2_monitor.sock,server,nowait -device e1000,netdev=nttsip1 \\\n-    -netdev user,id=nttsip1,hostfwd=tcp:127.0.0.1:6003-:22 \\\n-    -chardev socket,id=char0,path=./vhost-net1,server \\\n-    -netdev type=vhost-user,id=netdev0,chardev=char0,vhostforce,queues=8 \\\n-    -device virtio-net-pci,netdev=netdev0,mac=52:54:00:00:00:02,disable-modern=false,mrg_rxbuf=off,mq=on,vectors=40,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,guest_ufo=on,host_ufo=on -vnc :12\n+      taskset -c 17-27 qemu-system-x86_64 -name vm2 -enable-kvm -cpu host -smp 9 -m 4096 \\\n+      -object memory-backend-file,id=mem,size=4096M,mem-path=/mnt/huge,share=on \\\n+      -numa node,memdev=mem -mem-prealloc -drive file=/home/osimg/ubuntu22-04-2.img  \\\n+      -chardev socket,path=/tmp/vm2_qga0.sock,server,nowait,id=vm2_qga0 -device virtio-serial \\\n+      -device virtserialport,chardev=vm2_qga0,name=org.qemu.guest_agent.2 -daemonize \\\n+      -monitor unix:/tmp/vm2_monitor.sock,server,nowait -device e1000,netdev=nttsip1 \\\n+      -netdev user,id=nttsip1,hostfwd=tcp:127.0.0.1:6003-:22 \\\n+      -chardev socket,id=char0,path=./vhost-net1,server \\\n+      -netdev type=vhost-user,id=netdev0,chardev=char0,vhostforce,queues=8 \\\n+      -device virtio-net-pci,netdev=netdev0,mac=52:54:00:00:00:02,disable-modern=false,mrg_rxbuf=off,mq=on,vectors=40,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,guest_ufo=on,host_ufo=on -vnc :12\n \n-8. Bind virtio device with vfio-pci driver::\n+8. On VM2, bind virtio device with vfio-pci driver::\n \n-    modprobe vfio\n-    modprobe vfio-pci\n-    echo 1 > /sys/module/vfio/parameters/enable_unsafe_noiommu_mode\n-    <dpdk dir># ./usertools/dpdk-devbind.py --force --bind=vfio-pci 0000:00:05.0\n+      modprobe vfio\n+      modprobe vfio-pci\n+      echo 1 > /sys/module/vfio/parameters/enable_unsafe_noiommu_mode\n+      <dpdk dir># ./usertools/dpdk-devbind.py --force --bind=vfio-pci 0000:00:05.0\n \n 9. Launch testpmd in VM2 and send imix pkts from VM2::\n \n-\t<dpdk dir># ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -c 0x3 -n 4 -- -i --tx-offloads=0x00 --enable-hw-vlan-strip \\\n-\t--txq=8 --rxq=8 --txd=1024 --rxd=1024 --max-pkt-len=9600 --rx-offloads=0x00002000\n-\ttestpmd> set fwd mac\n-\ttestpmd> set txpkts 64,256,512,1024,2000,64,256,512,1024,2000\n+      <dpdk dir># ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -c 0x3 -n 4 -- -i --tx-offloads=0x00 --enable-hw-vlan-strip \\\n+      --txq=8 --rxq=8 --txd=1024 --rxd=1024 --max-pkt-len=9600 --rx-offloads=0x00002000\n+      testpmd> set fwd mac\n+      testpmd> set txpkts 64,256,512,1024,2000,64,256,512,1024,2000\n \n-10. Check imix packets can looped between two VMs and 4 queues all have packets rx/tx::\n+10. Check imix packets can loop between two VMs and 4 queues all have packets rx/tx::\n \n-\ttestpmd> show port stats all\n-\ttestpmd> stop\n-\ttestpmd> start\n+      testpmd> show port stats all\n+      testpmd> stop\n+      testpmd> start\n \n 11. Check vhost use the asynchronous data path(funtion like virtio_dev_rx_async_xxx/virtio_dev_tx_async_xxx)::\n \n-\tperf top\n+      perf top\n \n 12. On host, dynamic change queue numbers::\n \n-\ttestpmd> stop\n-\ttestpmd> port stop all\n-\ttestpmd> port config all rxq 8\n-\ttestpmd> port config all txq 8\n-\ttestpmd> port start all\n-\ttestpmd> start\n+      testpmd> stop\n+      testpmd> port stop all\n+      testpmd> port config all rxq 8\n+      testpmd> port config all txq 8\n+      testpmd> port start all\n+      testpmd> start\n \n 13. Send packets by testpmd in VM2::\n \n-\ttestpmd> stop\n-\ttestpmd> start tx_first 32\n-\ttestpmd> show port stats all\n+      testpmd> stop\n+      testpmd> start tx_first 32\n+      testpmd> show port stats all\n \n-14. Check vhost testpmd RX/TX can work normally, packets can looped between two VMs and both 8 queues can RX/TX traffic.\n+14. Check vhost testpmd RX/TX can work normally, packets can loop between two VMs and both 8 queues can RX/TX traffic.\n \n 15. Rerun step 11.\n \n Test Case 4: VM2VM virtio-pmd packed ring non-mergeable path dynamic queue size with cbdma enable and server mode\n -----------------------------------------------------------------------------------------------------------------\n-This case tests packed ring non-mergeable path with virtio1.1 and server mode in VM2VM vhost-user/virtio-pmd topology when vhost uses the asynchronous operations with CBDMA channels,check that it can work normally after dynamically changing queue number.\n+This case tests packed ring non-mergeable path with virtio1.1 and server mode in VM2VM vhost-user/virtio-pmd topology\n+when vhost uses the asynchronous operations with CBDMA channels,check that it can work normally after dynamically changing queue number.\n \n 1. Bind 16 CBDMA channels to vfio-pci, as common step 1.\n \n 2. Launch the testpmd with 2 vhost ports below commands::\n \n-    ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -l 1-5 -n 4 --file-prefix=vhost -a 0000:00:04.0 -a 0000:00:04.1 -a 0000:00:04.2 -a 0000:00:04.3 -a 0000:00:04.4 -a 0000:00:04.5 -a 0000:00:04.6 -a 0000:00:04.7 \\\n-    -a 0000:80:04.0 -a 0000:80:04.1 -a 0000:80:04.2 -a 0000:80:04.3 -a 0000:80:04.4 -a 0000:80:04.5 -a 0000:80:04.6 -a 0000:80:04.7 \\\n-    --vdev 'net_vhost0,iface=vhost-net0,client=1,queues=8,dmas=[txq0;txq1;txq2;txq3;txq4;txq5;rxq2;rxq3;rxq4;rxq5;rxq6;rxq7]' \\\n-    --vdev 'net_vhost1,iface=vhost-net1,client=1,queues=8,dmas=[txq0;txq1;txq2;txq3;txq4;txq5;rxq2;rxq3;rxq4;rxq5;rxq6;rxq7]' \\\n-    -- -i --nb-cores=4 --txd=1024 --rxd=1024 --rxq=8 --txq=8 \\\n-    --lcore-dma=[lcore2@0000:00:04.0,lcore2@0000:00:04.1,lcore2@0000:00:04.2,lcore2@0000:00:04.3,lcore3@0000:00:04.4,lcore3@0000:00:04.5,lcore3@0000:00:04.6,lcore3@0000:00:04.7,lcore4@0000:80:04.0,lcore4@0000:80:04.1,lcore4@0000:80:04.2,lcore4@0000:80:04.3,lcore5@0000:80:04.4,lcore5@0000:80:04.5,lcore5@0000:80:04.6,lcore5@0000:80:04.7]\n-    testpmd> start\n+      ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -l 1-5 -n 4 --file-prefix=vhost \\\n+      -a 0000:00:04.0 -a 0000:00:04.1 -a 0000:00:04.2 -a 0000:00:04.3 -a 0000:00:04.4 -a 0000:00:04.5 -a 0000:00:04.6 -a 0000:00:04.7 \\\n+      -a 0000:80:04.0 -a 0000:80:04.1 -a 0000:80:04.2 -a 0000:80:04.3 -a 0000:80:04.4 -a 0000:80:04.5 -a 0000:80:04.6 -a 0000:80:04.7 \\\n+      --vdev 'net_vhost0,iface=vhost-net0,client=1,queues=8,dmas=[txq0@0000:00:04.0;txq1@0000:00:04.1;txq2@0000:00:04.2;txq3@0000:00:04.3;txq4@0000:00:04.4;txq5@0000:00:04.1;rxq2@0000:00:04.2;rxq3@0000:00:04.3;rxq4@0000:00:04.4;rxq5@0000:00:04.5;rxq6@0000:00:04.6;rxq7@0000:00:04.7]' \\\n+      --vdev 'net_vhost1,iface=vhost-net1,client=1,queues=8,dmas=[txq0@0000:80:04.0;txq1@0000:80:04.1;txq2@0000:80:04.2;txq3@0000:80:04.3;txq4@0000:80:04.4;txq5@0000:80:04.1;rxq2@0000:80:04.2;rxq3@0000:80:04.3;rxq4@0000:80:04.4;rxq5@0000:80:04.5;rxq6@0000:80:04.6;rxq7@0000:80:04.7]' \\\n+      -- -i --nb-cores=4 --txd=1024 --rxd=1024 --rxq=8 --txq=8\n+      testpmd> start\n \n 3. Launch VM1 and VM2 using qemu::\n \n-    taskset -c 6-16 qemu-system-x86_64 -name vm1 -enable-kvm -cpu host -smp 9 -m 4096 \\\n-    -object memory-backend-file,id=mem,size=4096M,mem-path=/mnt/huge,share=on \\\n-    -numa node,memdev=mem -mem-prealloc -drive file=/home/osimg/ubuntu20-04.img  \\\n-    -chardev socket,path=/tmp/vm1_qga0.sock,server,nowait,id=vm1_qga0 -device virtio-serial \\\n-    -device virtserialport,chardev=vm1_qga0,name=org.qemu.guest_agent.2 -daemonize \\\n-    -monitor unix:/tmp/vm1_monitor.sock,server,nowait -device e1000,netdev=nttsip1 \\\n-    -netdev user,id=nttsip1,hostfwd=tcp:127.0.0.1:6002-:22 \\\n-    -chardev socket,id=char0,path=./vhost-net0,server \\\n-    -netdev type=vhost-user,id=netdev0,chardev=char0,vhostforce,queues=8 \\\n-    -device virtio-net-pci,netdev=netdev0,mac=52:54:00:00:00:01,disable-modern=false,mrg_rxbuf=off,mq=on,vectors=40,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,guest_ufo=on,host_ufo=on,packed=on -vnc :10\n-\n-    taskset -c 17-27 qemu-system-x86_64 -name vm2 -enable-kvm -cpu host -smp 9 -m 4096 \\\n-    -object memory-backend-file,id=mem,size=4096M,mem-path=/mnt/huge,share=on \\\n-    -numa node,memdev=mem -mem-prealloc -drive file=/home/osimg/ubuntu20-04-2.img  \\\n-    -chardev socket,path=/tmp/vm2_qga0.sock,server,nowait,id=vm2_qga0 -device virtio-serial \\\n-    -device virtserialport,chardev=vm2_qga0,name=org.qemu.guest_agent.2 -daemonize \\\n-    -monitor unix:/tmp/vm2_monitor.sock,server,nowait -device e1000,netdev=nttsip1 \\\n-    -netdev user,id=nttsip1,hostfwd=tcp:127.0.0.1:6003-:22 \\\n-    -chardev socket,id=char0,path=./vhost-net1,server \\\n-    -netdev type=vhost-user,id=netdev0,chardev=char0,vhostforce,queues=8 \\\n-    -device virtio-net-pci,netdev=netdev0,mac=52:54:00:00:00:02,disable-modern=false,mrg_rxbuf=off,mq=on,vectors=40,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,guest_ufo=on,host_ufo=on,packed=on -vnc :12\n+      taskset -c 6-16 qemu-system-x86_64 -name vm1 -enable-kvm -cpu host -smp 9 -m 4096 \\\n+      -object memory-backend-file,id=mem,size=4096M,mem-path=/mnt/huge,share=on \\\n+      -numa node,memdev=mem -mem-prealloc -drive file=/home/osimg/ubuntu22-04.img  \\\n+      -chardev socket,path=/tmp/vm1_qga0.sock,server,nowait,id=vm1_qga0 -device virtio-serial \\\n+      -device virtserialport,chardev=vm1_qga0,name=org.qemu.guest_agent.2 -daemonize \\\n+      -monitor unix:/tmp/vm1_monitor.sock,server,nowait -device e1000,netdev=nttsip1 \\\n+      -netdev user,id=nttsip1,hostfwd=tcp:127.0.0.1:6002-:22 \\\n+      -chardev socket,id=char0,path=./vhost-net0,server \\\n+      -netdev type=vhost-user,id=netdev0,chardev=char0,vhostforce,queues=8 \\\n+      -device virtio-net-pci,netdev=netdev0,mac=52:54:00:00:00:01,disable-modern=false,mrg_rxbuf=off,mq=on,vectors=40,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,guest_ufo=on,host_ufo=on,packed=on -vnc :10\n+\n+      taskset -c 17-27 qemu-system-x86_64 -name vm2 -enable-kvm -cpu host -smp 9 -m 4096 \\\n+      -object memory-backend-file,id=mem,size=4096M,mem-path=/mnt/huge,share=on \\\n+      -numa node,memdev=mem -mem-prealloc -drive file=/home/osimg/ubuntu22-04-2.img  \\\n+      -chardev socket,path=/tmp/vm2_qga0.sock,server,nowait,id=vm2_qga0 -device virtio-serial \\\n+      -device virtserialport,chardev=vm2_qga0,name=org.qemu.guest_agent.2 -daemonize \\\n+      -monitor unix:/tmp/vm2_monitor.sock,server,nowait -device e1000,netdev=nttsip1 \\\n+      -netdev user,id=nttsip1,hostfwd=tcp:127.0.0.1:6003-:22 \\\n+      -chardev socket,id=char0,path=./vhost-net1,server \\\n+      -netdev type=vhost-user,id=netdev0,chardev=char0,vhostforce,queues=8 \\\n+      -device virtio-net-pci,netdev=netdev0,mac=52:54:00:00:00:02,disable-modern=false,mrg_rxbuf=off,mq=on,vectors=40,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,guest_ufo=on,host_ufo=on,packed=on -vnc :12\n \n 4. On VM1 and VM2, bind virtio device with vfio-pci driver::\n \n-    modprobe vfio\n-    modprobe vfio-pci\n-    echo 1 > /sys/module/vfio/parameters/enable_unsafe_noiommu_mode\n-    ./usertools/dpdk-devbind.py --force --bind=vfio-pci 0000:00:05.0\n+      modprobe vfio\n+      modprobe vfio-pci\n+      echo 1 > /sys/module/vfio/parameters/enable_unsafe_noiommu_mode\n+      ./usertools/dpdk-devbind.py --force --bind=vfio-pci 0000:00:05.0\n \n 5. Launch testpmd in VM1::\n \n-    ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -c 0x3 -n 4 -- -i --tx-offloads=0x00 --enable-hw-vlan-strip --txq=4 --rxq=4 --txd=1024 --rxd=1024\n-    testpmd> set mac fwd\n-    testpmd> start\n+      ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -c 0x3 -n 4 -- -i --tx-offloads=0x00 --enable-hw-vlan-strip --txq=4 --rxq=4 --txd=1024 --rxd=1024\n+      testpmd> set mac fwd\n+      testpmd> start\n \n-6. Launch testpmd in VM2 and send imix pkts, check imix packets can looped between two VMs for 1 mins::\n+6. Launch testpmd in VM2 and send imix pkts, check imix packets can loop between two VMs for 1 mins::\n \n-    ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -c 0x3 -n 4 -- -i --tx-offloads=0x00 --enable-hw-vlan-strip --txq=4 --rxq=4 --txd=1024 --rxd=1024\n-    testpmd> set mac fwd\n-    testpmd> set txpkts 64,256,512\n-    testpmd> start tx_first 32\n-    testpmd> show port stats all\n+      ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -c 0x3 -n 4 -- -i --tx-offloads=0x00 --enable-hw-vlan-strip --txq=4 --rxq=4 --txd=1024 --rxd=1024\n+      testpmd> set mac fwd\n+      testpmd> set txpkts 64,256,512\n+      testpmd> start tx_first 32\n+      testpmd> show port stats all\n \n 7. Check vhost use the asynchronous data path(funtion like virtio_dev_rx_async_xxx/virtio_dev_tx_async_xxx)::\n \n-    perf top\n+      perf top\n \n 8. On VM2, stop the testpmd, check that both 4 queues have packets rx/tx::\n \n-    testpmd> stop\n+      testpmd> stop\n \n 9. On VM1 and VM2, dynamic change queue numbers at virtio-pmd side from 4 queues to 8 queues::\n \n-    testpmd> stop\n-    testpmd> port stop all\n-    testpmd> port config all rxq 8\n-    testpmd> port config all txq 8\n-    testpmd> port start all\n-    testpmd> start\n+      testpmd> stop\n+      testpmd> port stop all\n+      testpmd> port config all rxq 8\n+      testpmd> port config all txq 8\n+      testpmd> port start all\n+      testpmd> start\n \n-10. Send packets by testpmd in VM2, check Check virtio-pmd RX/TX can work normally and imix packets can looped between two VMs for 1 mins::\n+10. Send packets by testpmd in VM2, check Check virtio-pmd RX/TX can work normally and imix packets can loop between two VMs for 1 mins::\n \n-\ttestpmd> stop\n-\ttestpmd> start tx_first 32\n-\ttestpmd> show port stats all\n+      testpmd> stop\n+      testpmd> start tx_first 32\n+      testpmd> show port stats all\n \n 11. Rerun step 7.\n \n",
    "prefixes": [
        "V2",
        "1/2"
    ]
}