[v2] net/mlx5: fix port's event cleaning order

Message ID 20221109222938.266140-1-michaelba@nvidia.com (mailing list archive)
State Accepted, archived
Delegated to: Raslan Darawsheh
Headers
Series [v2] net/mlx5: fix port's event cleaning order |

Checks

Context Check Description
ci/checkpatch success coding style OK
ci/github-robot: build success github build: passed
ci/Intel-compilation success Compilation OK
ci/intel-Testing success Testing PASS
ci/iol-mellanox-Performance success Performance Testing PASS
ci/iol-intel-Functional success Functional Testing PASS
ci/iol-intel-Performance success Performance Testing PASS
ci/iol-aarch64-unit-testing success Testing PASS
ci/iol-x86_64-compile-testing success Testing PASS
ci/iol-x86_64-unit-testing success Testing PASS
ci/iol-aarch64-compile-testing success Testing PASS

Commit Message

Michael Baum Nov. 9, 2022, 10:29 p.m. UTC
The shared IB device (sh) has per port data with filed for interrupt
handler port_id. It used by shared interrupt handler to find the
corresponding rte_eth device by IB port index.
If value is equal or greater RTE_MAX_ETHPORTS it means there is no
subhandler installed for specified IB port index.

When a few ports are created under same sh, the sh is created with the
first port and the interrupt handler port_id is initialized to
RTE_MAX_ETHPORTS for each port.
In port creation, the interrupt handler port_id is updated with the
correct value. Since this updating, the mlx5_dev_interrupt_nl_cb
function uses this port and its priv structure.
However, when the ports are closed, this filed isn't updated and the
interrupt handler continue working until it is uninstalled in SH
destruction.
If mlx5_dev_interrupt_nl_cb is called between port closing and SH
destruction, it uses invalid port causing a crash.

This patch adds interrupt handler port_id updating to the close function
and add memory barrier to make sure it is done before priv reset.

Fixes: 655c3c26c11e ("net/mlx5: fix initial link status detection")
Cc: dkozlyuk@nvidia.com
Cc: stable@dpdk.org

Signed-off-by: Michael Baum <michaelba@nvidia.com>
Acked-by: Matan Azrad <matan@nvidia.com>
---

v2: fix typo in commit message.

 drivers/net/mlx5/linux/mlx5_os.c | 3 +++
 drivers/net/mlx5/mlx5.c          | 6 ++++++
 2 files changed, 9 insertions(+)
  

Comments

Raslan Darawsheh Nov. 10, 2022, 12:17 p.m. UTC | #1
Hi,

> -----Original Message-----
> From: Michael Baum <michaelba@nvidia.com>
> Sent: Thursday, November 10, 2022 12:30 AM
> To: dev@dpdk.org
> Cc: Matan Azrad <matan@nvidia.com>; Raslan Darawsheh
> <rasland@nvidia.com>; Slava Ovsiienko <viacheslavo@nvidia.com>;
> dkozlyuk@nvidia.com; stable@dpdk.org
> Subject: [PATCH v2] net/mlx5: fix port's event cleaning order
> 
> The shared IB device (sh) has per port data with filed for interrupt
> handler port_id. It used by shared interrupt handler to find the
> corresponding rte_eth device by IB port index.
> If value is equal or greater RTE_MAX_ETHPORTS it means there is no
> subhandler installed for specified IB port index.
> 
> When a few ports are created under same sh, the sh is created with the
> first port and the interrupt handler port_id is initialized to
> RTE_MAX_ETHPORTS for each port.
> In port creation, the interrupt handler port_id is updated with the
> correct value. Since this updating, the mlx5_dev_interrupt_nl_cb
> function uses this port and its priv structure.
> However, when the ports are closed, this filed isn't updated and the
> interrupt handler continue working until it is uninstalled in SH
> destruction.
> If mlx5_dev_interrupt_nl_cb is called between port closing and SH
> destruction, it uses invalid port causing a crash.
> 
> This patch adds interrupt handler port_id updating to the close function
> and add memory barrier to make sure it is done before priv reset.
> 
> Fixes: 655c3c26c11e ("net/mlx5: fix initial link status detection")
> Cc: dkozlyuk@nvidia.com
> Cc: stable@dpdk.org
> 
> Signed-off-by: Michael Baum <michaelba@nvidia.com>
> Acked-by: Matan Azrad <matan@nvidia.com>
> ---
> 
> v2: fix typo in commit message.
> 

Patch applied to next-net-mlx,

Kindest regards,
Raslan Darawsheh
  

Patch

diff --git a/drivers/net/mlx5/linux/mlx5_os.c b/drivers/net/mlx5/linux/mlx5_os.c
index 2b6741396d..a71474c90a 100644
--- a/drivers/net/mlx5/linux/mlx5_os.c
+++ b/drivers/net/mlx5/linux/mlx5_os.c
@@ -1676,6 +1676,9 @@  mlx5_dev_spawn(struct rte_device *dpdk_dev,
 	return eth_dev;
 error:
 	if (priv) {
+		priv->sh->port[priv->dev_port - 1].nl_ih_port_id =
+							       RTE_MAX_ETHPORTS;
+		rte_io_wmb();
 #ifdef HAVE_MLX5_HWS_SUPPORT
 		if (eth_dev &&
 		    priv->sh &&
diff --git a/drivers/net/mlx5/mlx5.c b/drivers/net/mlx5/mlx5.c
index 1cf6df6049..95b0151fbc 100644
--- a/drivers/net/mlx5/mlx5.c
+++ b/drivers/net/mlx5/mlx5.c
@@ -2137,6 +2137,12 @@  mlx5_dev_close(struct rte_eth_dev *dev)
 		if (!c)
 			claim_zero(rte_eth_switch_domain_free(priv->domain_id));
 	}
+	priv->sh->port[priv->dev_port - 1].nl_ih_port_id = RTE_MAX_ETHPORTS;
+	/*
+	 * The interrupt handler port id must be reset before priv is reset
+	 * since 'mlx5_dev_interrupt_nl_cb' uses priv.
+	 */
+	rte_io_wmb();
 	memset(priv, 0, sizeof(*priv));