@@ -55,6 +55,9 @@ Configuration information
- **CONFIG_RTE_LIBRTE_ENIC_DEBUG** (default n): Enables or disables debug
logging within the ENIC PMD driver.
+ - **CONFIG_RTE_LIBRTE_ENIC_DEBUG_FLOW** (default n): Enables or disables flow
+ API related debug logging within the ENIC PMD driver.
+
- **vNIC Configuration Parameters**
- **Number of Queues**
@@ -66,7 +69,7 @@ Configuration information
These values should be configured as follows:
- The number of WQs should be greater or equal to the value of the
- expected nb_tx_q parameter in the call to the
+ expected nb_tx_q parameter in the call to
rte_eth_dev_configure()
- The number of RQs configured in the vNIC should be greater or
@@ -88,7 +91,7 @@ Configuration information
- **Size of Queues**
Likewise, the number of receive and transmit descriptors are configurable on
- a per vNIC bases via the UCS Manager and should be greater than or equal to
+ a per-vNIC basis via the UCS Manager and should be greater than or equal to
the nb_rx_desc and nb_tx_desc parameters expected to be used in the calls
to rte_eth_rx_queue_setup() and rte_eth_tx_queue_setup() respectively.
An application requesting more than the set size will be limited to that
@@ -101,7 +104,7 @@ Configuration information
- *Note*: Since the introduction of Rx scatter, for performance
reasons, this PMD uses two RQs on the vNIC per receive queue in
- DPDK. One RQ holds descriptors for the start of a packet the
+ DPDK. One RQ holds descriptors for the start of a packet, and the
second RQ holds the descriptors for the rest of the fragments of
a packet. This means that the nb_rx_desc parameter to
rte_eth_rx_queue_setup() can be a greater than 4096. The exact
@@ -110,7 +113,7 @@ Configuration information
For example: If the mbuf size is 2048, and the MTU is 9000, then
receiving a full size packet will take 5 descriptors, 1 from the
- start of packet queue, and 4 from the second queue. Assuming
+ start-of-packet queue, and 4 from the second queue. Assuming
that the RQ size was set to the maximum of 4096, then the
application can specify up to 1024 + 4096 as the nb_rx_desc
parameter to rte_eth_rx_queue_setup().
@@ -156,7 +159,7 @@ host to route intra-host VM traffic.
Please refer to `Creating a Dynamic vNIC Connection Policy
<http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/vm_fex/vmware/gui/config_guide/b_GUI_VMware_VM-FEX_UCSM_Configuration_Guide/b_GUI_VMware_VM-FEX_UCSM_Configuration_Guide_chapter_010.html#task_433E01651F69464783A68E66DA8A47A5>`_
-for information on configuring SR-IOV Adapter policies using UCS manager.
+for information on configuring SR-IOV adapter policies using UCS manager.
Once the policies are in place and the host OS is rebooted, VFs should be
visible on the host, E.g.:
@@ -222,15 +225,15 @@ Generic Flow API is supported. The baseline support is:
- **1200 series VICs**
- 5-tuple exact Flow support for 1200 series adapters. This allows:
+ 5-tuple exact flow support for 1200 series adapters. This allows:
- Attributes: ingress
- Items: ipv4, ipv6, udp, tcp (must exactly match src/dst IP
- addresses and ports and all must be specified).
+ addresses and ports and all must be specified)
- Actions: queue and void
- Selectors: 'is'
-- **1300 series VICS with Advanced filters disabled**
+- **1300 series VICS with advanced filters disabled**
With advanced filters disabled, an IPv4 or IPv6 item must be specified
in the pattern.
@@ -239,15 +242,15 @@ Generic Flow API is supported. The baseline support is:
- Items: eth, ipv4, ipv6, udp, tcp, vxlan, inner eth, ipv4, ipv6, udp, tcp
- Actions: queue and void
- Selectors: 'is', 'spec' and 'mask'. 'last' is not supported
- - In total, up to 64 bytes of mask is allowed across all haeders
+ - In total, up to 64 bytes of mask is allowed across all headers
-- **1300 series VICS with Advanced filters enabled**
+- **1300 series VICS with advanced filters enabled**
- Attributes: ingress
- Items: eth, ipv4, ipv6, udp, tcp, vxlan, inner eth, ipv4, ipv6, udp, tcp
- Actions: queue, mark, flag and void
- Selectors: 'is', 'spec' and 'mask'. 'last' is not supported
- - In total, up to 64 bytes of mask is allowed across all haeders
+ - In total, up to 64 bytes of mask is allowed across all headers
More features may be added in future firmware and new versions of the VIC.
Please refer to the release notes.
@@ -268,8 +271,8 @@ Limitations
connected point-to-point to another adapter port or connected though a router
instead of a switch, all ingress packets will be VLAN tagged. Programs such
as l3fwd which do not account for VLAN tags in packets will misbehave. The
- solution is to enable VLAN stripping on ingress. The follow code fragment is
- example of how to accomplish this:
+ solution is to enable VLAN stripping on ingress. The following code fragment is
+ an example of how to accomplish this:
.. code-block:: console
@@ -291,7 +294,7 @@ Limitations
- VF devices are not usable directly from the host. They can only be used
as assigned devices on VM instances.
- Currently, unbind of the ENIC kernel mode driver 'enic.ko' on the VM
- instance may hang. As a workaround, enic.ko should blacklisted or removed
+ instance may hang. As a workaround, enic.ko should be blacklisted or removed
from the boot process.
- pci_generic cannot be used as the uio module in the VM. igb_uio or
vfio in non-IOMMU mode can be used.
@@ -304,7 +307,7 @@ Limitations
- The number of filters that can be specified with the Generic Flow API is
dependent on how many header fields are being masked. Use 'flow create' in
a loop to determine how many filters your VIC will support (not more than
- 1000 for 1300 series VICs). Filter are checked for matching in the order they
+ 1000 for 1300 series VICs). Filters are checked for matching in the order they
were added. Since there currently is no grouping or priority support,
'catch-all' filters should be added last.
@@ -317,8 +320,6 @@ the ENIC PMD library will be built into the DPDK library.
Refer to the document :ref:`compiling and testing a PMD for a NIC
<pmd_build_and_test>` for details.
-By default the ENIC PMD library will be built into the DPDK library.
-
For configuring and using UIO and VFIO frameworks, please refer to the
documentation that comes with DPDK suite.
@@ -363,7 +364,7 @@ Supported features
- IPV4, IPV6 and TCP RSS hashing
- Scattered Rx
- MTU update
-- SR-IOV on UCS managed servers connected to Fabric Interconnects.
+- SR-IOV on UCS managed servers connected to Fabric Interconnects
- Flow API
Known bugs and unsupported features in this release
@@ -372,7 +373,7 @@ Known bugs and unsupported features in this release
- Signature or flex byte based flow direction
- Drop feature of flow direction
- VLAN based flow direction
-- non-IPV4 flow direction
+- Non-IPV4 flow direction
- Setting of extended VLAN
- UDP RSS hashing
- MTU update only works if Scattered Rx mode is disabled
@@ -381,15 +382,15 @@ Prerequisites
-------------
- Prepare the system as recommended by DPDK suite. This includes environment
- variables, hugepages configuration, tool-chains and configuration
+ variables, hugepages configuration, tool-chains and configuration.
- Insert vfio-pci kernel module using the command 'modprobe vfio-pci' if the
- user wants to use VFIO framework
+ user wants to use VFIO framework.
- Insert uio kernel module using the command 'modprobe uio' if the user wants
- to use UIO framework
+ to use UIO framework.
- DPDK suite should be configured based on the user's decision to use VFIO or
- UIO framework
+ UIO framework.
- If the vNIC device(s) to be used is bound to the kernel mode Ethernet driver
- use 'ifconfig' to bring the interface down. The dpdk-devbind.py tool can
+ use 'ip' to bring the interface down. The dpdk-devbind.py tool can
then be used to unbind the device's bus id from the ENIC kernel mode driver.
- Bind the intended vNIC to vfio-pci in case the user wants ENIC PMD to use
VFIO framework using dpdk-devbind.py.
@@ -422,7 +423,8 @@ libraries and the initialization time of the application.
Additional Reference
--------------------
-- http://www.cisco.com/c/en/us/products/servers-unified-computing
+- https://www.cisco.com/c/en/us/products/servers-unified-computing/index.html
+- https://www.cisco.com/c/en/us/products/interfaces-modules/unified-computing-system-adapters/index.html
Contact Information
-------------------