Suanming Mou Oct. 23, 2020, 7:14 a.m. UTC
  This commit adds the spinlock for the meter action to make it be thread
safe. Atomic reference counter in all is not enough as the meter action
should be created synchronized with reference counter increment. With
only atomic reference counter, even the counter is increased, the action
may still not be created.

Signed-off-by: Suanming Mou <suanmingm@nvidia.com>
Acked-by: Matan Azrad <matan@nvidia.com>
---
 drivers/net/mlx5/mlx5_flow.h       |  2 ++
 drivers/net/mlx5/mlx5_flow_meter.c | 72 ++++++++++++++++++++------------------
 2 files changed, 39 insertions(+), 35 deletions(-)
  

Patch

diff --git a/drivers/net/mlx5/mlx5_flow.h b/drivers/net/mlx5/mlx5_flow.h
index 52680ad..637922e 100644
--- a/drivers/net/mlx5/mlx5_flow.h
+++ b/drivers/net/mlx5/mlx5_flow.h
@@ -837,6 +837,8 @@  struct mlx5_flow_meter {
 	struct mlx5_flow_meter_profile *profile;
 	/**< Meter profile parameters. */
 
+	rte_spinlock_t sl; /**< Meter action spinlock. */
+
 	/** Policer actions (per meter output color). */
 	enum rte_mtr_policer_action action[RTE_COLORS];
 
diff --git a/drivers/net/mlx5/mlx5_flow_meter.c b/drivers/net/mlx5/mlx5_flow_meter.c
index b36bc7b..03a5e79 100644
--- a/drivers/net/mlx5/mlx5_flow_meter.c
+++ b/drivers/net/mlx5/mlx5_flow_meter.c
@@ -679,6 +679,7 @@ 
 	fm->shared = !!shared;
 	fm->policer_stats.stats_mask = params->stats_mask;
 	fm->profile->ref_cnt++;
+	rte_spinlock_init(&fm->sl);
 	return 0;
 error:
 	mlx5_flow_destroy_policer_rules(dev, fm, &attr);
@@ -1167,49 +1168,49 @@  struct mlx5_flow_meter *
 		       struct rte_flow_error *error)
 {
 	struct mlx5_flow_meter *fm;
+	int ret = 0;
 
 	fm = mlx5_flow_meter_find(priv, meter_id);
 	if (fm == NULL) {
 		rte_flow_error_set(error, ENOENT,
 				   RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL,
 				   "Meter object id not valid");
-		goto error;
-	}
-	if (!fm->shared && fm->ref_cnt) {
-		DRV_LOG(ERR, "Cannot share a non-shared meter.");
-		rte_flow_error_set(error, EINVAL,
-				  RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL,
-				  "Meter can't be shared");
-		goto error;
+		return fm;
 	}
-	if (!fm->ref_cnt++) {
-		MLX5_ASSERT(!fm->mfts->meter_action);
+	rte_spinlock_lock(&fm->sl);
+	if (fm->mfts->meter_action) {
+		if (fm->shared &&
+		    attr->transfer == fm->transfer &&
+		    attr->ingress == fm->ingress &&
+		    attr->egress == fm->egress)
+			fm->ref_cnt++;
+		else
+			ret = -1;
+	} else {
 		fm->ingress = attr->ingress;
 		fm->egress = attr->egress;
 		fm->transfer = attr->transfer;
+		 fm->ref_cnt = 1;
 		/* This also creates the meter object. */
 		fm->mfts->meter_action = mlx5_flow_meter_action_create(priv,
 								       fm);
-		if (!fm->mfts->meter_action)
-			goto error_detach;
-	} else {
-		MLX5_ASSERT(fm->mfts->meter_action);
-		if (attr->transfer != fm->transfer ||
-		    attr->ingress != fm->ingress ||
-		    attr->egress != fm->egress) {
-			DRV_LOG(ERR, "meter I/O attributes do not "
-				"match flow I/O attributes.");
-			goto error_detach;
+		if (!fm->mfts->meter_action) {
+			fm->ref_cnt = 0;
+			fm->ingress = 0;
+			fm->egress = 0;
+			fm->transfer = 0;
+			ret = -1;
+			DRV_LOG(ERR, "Meter action create failed.");
 		}
 	}
-	return fm;
-error_detach:
-	mlx5_flow_meter_detach(fm);
-	rte_flow_error_set(error, EINVAL, RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL,
-			  fm->mfts->meter_action ? "Meter attr not match" :
-			  "Meter action create failed");
-error:
-	return NULL;
+	rte_spinlock_unlock(&fm->sl);
+	if (ret)
+		rte_flow_error_set(error, EINVAL,
+				   RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL,
+				   fm->mfts->meter_action ?
+				   "Meter attr not match" :
+				   "Meter action create failed");
+	return ret ? NULL : fm;
 }
 
 /**
@@ -1222,15 +1223,16 @@  struct mlx5_flow_meter *
 mlx5_flow_meter_detach(struct mlx5_flow_meter *fm)
 {
 #ifdef HAVE_MLX5_DR_CREATE_ACTION_FLOW_METER
+	rte_spinlock_lock(&fm->sl);
 	MLX5_ASSERT(fm->ref_cnt);
-	if (--fm->ref_cnt)
-		return;
-	if (fm->mfts->meter_action)
+	if (--fm->ref_cnt == 0) {
 		mlx5_glue->destroy_flow_action(fm->mfts->meter_action);
-	fm->mfts->meter_action = NULL;
-	fm->ingress = 0;
-	fm->egress = 0;
-	fm->transfer = 0;
+		fm->mfts->meter_action = NULL;
+		fm->ingress = 0;
+		fm->egress = 0;
+		fm->transfer = 0;
+	}
+	rte_spinlock_unlock(&fm->sl);
 #else
 	(void)fm;
 #endif