humin (Q) May 7, 2021, 9:08 a.m. UTC
  From: Chengwen Feng <fengchengwen@huawei.com>

The hardware doesn't support counting the number of bytes that through
the fdir rule. Therefore, the corresponding out parameters (e.g.
bytes_set/bytes) is set to zero.

Fixes: fcba820d9b9e ("net/hns3: support flow director")
Cc: stable@dpdk.org

Signed-off-by: Chengwen Feng <fengchengwen@huawei.com>
Signed-off-by: Min Hu (Connor) <humin29@huawei.com>
---
 drivers/net/hns3/hns3_flow.c | 2 ++
 1 file changed, 2 insertions(+)
  

Patch

diff --git a/drivers/net/hns3/hns3_flow.c b/drivers/net/hns3/hns3_flow.c
index 65c7f6e..82810e0 100644
--- a/drivers/net/hns3/hns3_flow.c
+++ b/drivers/net/hns3/hns3_flow.c
@@ -223,6 +223,8 @@  hns3_counter_query(struct rte_eth_dev *dev, struct rte_flow *flow,
 	}
 	qc->hits_set = 1;
 	qc->hits = value;
+	qc->bytes_set = 0;
+	qc->bytes = 0;
 
 	return 0;
 }