[dpdk-dev,3/8] doc: added to known issue 6.10 and removed fixed issue 6.29 from rel_notes
Commit Message
Signed-off-by: Siobhan Butler <siobhan.a.butler@intel.com>
---
doc/guides/rel_notes/known_issues.rst | 38 +++++++----------------------------
1 file changed, 7 insertions(+), 31 deletions(-)
@@ -338,6 +338,12 @@ Not all variants of supported NIC types have been used in testing
| | |
| | The NIC device identifiers used during testing: |
| | |
+| | * Intel(R) Ethernet Controller XL710 for 40GbE QSFP+ [8086:1584] |
+| | |
+| | * Intel(R) Ethernet Controller XL710 for 40GbE QSFP+ [8086:1583] |
+| | |
+| | * Intel(R) Ethernet Controller X710 for 10GbE SFP+ [8086:1572] |
+| | |
| | * Intel® 82576 Gigabit Ethernet Controller [8086:10c9] |
| | |
| | * Intel® 82576 Quad Copper Gigabit Ethernet Controller [8086:10e8] |
@@ -940,37 +946,7 @@ Ethertype filter could receive other packets (non-assigned) in Niantic
| | |
+--------------------------------+--------------------------------------------------------------------------------------+
-Double VLAN does not work on Intel® 40G ethernet controller
------------------------------------------------------------
-
-+--------------------------------+--------------------------------------------------------------------------------------+
-| Title | Double VLAN does not work on Intel® 40G ethernet controller |
-| | |
-+================================+======================================================================================+
-| Reference # | IXA00386480 |
-| | |
-+--------------------------------+--------------------------------------------------------------------------------------+
-| Description | On Intel® 40G Ethernet Controller: |
-| | |
-| | Double VLAN does not work. This was confirmed a firmware issue which will be fixed |
-| | in later versions of firmware. |
-| | |
-+--------------------------------+--------------------------------------------------------------------------------------+
-| Implication | After setting double vlan to be enabled on a port, no packets can be transmitted out |
-| | on that port. |
-| | |
-+--------------------------------+--------------------------------------------------------------------------------------+
-| Resolution/ Workaround | None |
-| | |
-+--------------------------------+--------------------------------------------------------------------------------------+
-| Affected Environment/ Platform | All |
-| | |
-+--------------------------------+--------------------------------------------------------------------------------------+
-| Driver/Module | Poll Mode Driver (PMD) |
-| | |
-+--------------------------------+--------------------------------------------------------------------------------------+
-
-Cannot set link speed on Intel® 40G ethernet controller
+Cannot set link speed on Intel® 40GbE ethernet controller
-------------------------------------------------------
+--------------------------------+--------------------------------------------------------------------------------------+